Floor joist span tables for surveyors floor construction.
Timber roof joist span tables uk.
They also tell you what the maximum spacing should be between each section or timber member size of joists mm clear span c16 joist m clear span c24 joist m 47 x 95 47 x 120 47 x 145 47 x 170 47 x 195 47 x 220 1 77 2 40.
These span tables apply only to flat roof and roof with a slope of up to 10 degrees.
For spans in excess of 4 5 m two rows of strutting will be required positioned at the one third and two third span positions.
Solid timber joist sizes are provided in the bs 8103 3 span tables.
Where the joists span over 2 5m strutting is required to prevent joists twisting when loaded.
This is the distance between joist centres.
Solid timber strutting to be at least 38mm thick and be a minimum of three quarters of the joist depth.
Where the tables do not apply or where there are concentrated loads floor joists should be designed by an engineer in accordance with technical requirement r5.
The weight of the timber floor itself consists of the timber joists the plasterboard ceiling underneath it except for suspended timber ground floors the floorboards and the nails or screws used to fix both of the aforementioned coverings.
Surveyors span tables for designing roof rafters.
Span tables for solid timber joists.
Proprietary strutting is to be used in accordance with manufacturers recommendations.
Joist spans 2 5m to 4 5m provide strutting at mid span.
Timber floor joists shall be adequate for the spans and loads and be correctly installed.
For pitched roofs flat roofs and ceiling joists.
Notches are not to exceed 0 125 of the depth of the joist and are to be located between 0 07 and 0 25 of the span from the support.
Span tables for flat roof joists to bs 5268 7 2 imposed loads of 0 75 kn m for maintenance and snow load are applicable where there is no permanent access no fixed ladder or staircase and most areas where the altitude does not exceed 100 metres refer to bs 6399 3.
Surveyors and structural engineers utilise data from tables below to help calculate the correct size strength and centres of roof timbers for the required spans and loadings.
Timber to be covered these span tables do not apply to timber which is fully exposed to the elements.
For spans of between 2 5 and 4 5 m one row of strutting is needed at the mid span position.